___________________________________________________ ___________________________________________________ ________________________ 1 of 4 sl power electronics corp ? 6050 king drive ventura, ca 93003 ? phone 805.486.4565 ? fax 858.712.2040 ? email: info@slpower.com ? www.slpower.com ac input 100-240vac, 50/60 hz, 1 ? . 90-270vac, 45-65 hz max turn on time 500 ms max input current 120vac: 4.2a. 230vac: 2.1a hold - up time 20 ms at 400w inrush curr ent active circuit, 37a max. peak over/undershoot 3.5% max input fuses f1 and f2, 6.3a/250v for line and neutral overlo ad protection cycling type, 470w typical power facto r 0.99 typical, 0.96 minimum overvoltage protection see chart earth leakage current 100 a at 120vac, 60 hz normal 400 a at 264vac, 50 hz, sfc ripple and noise 1% pk-pk max., 20mhz bw 0.1 f and 10 f caps on probe output power 400w continuous with 200lfm airflow see chart for convection ratings ite safety standards csa/en/iec/ul 60950-1 peak output power 450w for 1 minute, 10% duty cycle medical safety standards en/iec/ul 60601-1, csa22.2 no. 601-1 output voltage see chart thermal considerations keeping the following components below these temp. indicates sufficient cooling: t5: 90 c max., t1: 100 c max voltage adjustability 5% minimum switching frequency output: 170khz 8khz, pfc: 140khz 8khz minimum load not required mtbf 300k hours per telcordia total regulation see chart overtemperature protection automatic transient resp onse 500 s to 1%, 50% load step, i/ t < 0.2a/ s maximum voltage deviation is 3.5% efficiency 91% typical at 230vac 88% typical at 120vac remote sense compensates for up to 500mv voltage drop temperature coefficient 0.03% per c typical on all units model number key x output connections: "b" = busbars, "t" = phoenix p/ n 1731721 x cover options: blank = standard mini cover, "e" = c over w ith fan on the end, "t" = cover w ith fan on t op gnt rohs com pliant product fam ily 4 output pow er (watts): "4" = 400w xx output voltage: (see m odels chart below ) x input connections: "a" = eby p/n 5002-03-n-12, "b" = phoenix p/n 1732034, "c" = amp p/n 540445-5 (pin s 2 & 4 g GNT400 front end series 400w ac/dc universal input medical & ite power supply 2 year warranty ? medical (en60601-1) and ite (en60950) certification s ? compact 4? x 7? x 1.5? u channel (1u compatible) ? 9.5 w/in3 ? 100-240 vac input with active pfc ? 12 to 48 v dc output at 400w (300w convection rati ng) ? 5 vdc, 100 ma standby output ? 12 vdc fan output ? approved to ul, csa, and en/iec standards ? less than 100 a leakage ? compliance to en55011/22 conducted noise, class b ? rohs compliant ? category 6 specifications all specifications are typical at nominal input, fu ll load at 25 c unless otherwise stated .
___________________________________________________ ___________________________________________________ ________________________ 2 of 4 sl power electronics corp ? 6050 king drive ventura, ca 93003 ? phone 805.486.4565 ? fax 858.712.2040 ? email: info@slpower.com ? www.slpower.com gnt412abg 12v 25.0a 33.3a 120mv 2% 14.0 1v gnt415abg 15v 20.0a 26.7a 150mv 2% 17.6 1v gnt418abg 18v 16.7a 22.2a 180mv 2% 20.8 1v gnt424abg 24v 12.5a 16.7a 240mv 2% 26.5 1v gnt428abg 28v 10.7a 14.3a 280mv 2% 32.0 1v gnt436abg 36v 8.3a 11.1a 360mv 2% 39.0 1v gnt448abg 48v 6.3a 8.4a 480mv 2% 55.0 2v notes: 1. when the input voltage is <90vac, derate output pow er to 300w fan cooled or 250w convection. 2. using the t or e cover options allows for 400w cont inuous operation up to 40 c ambient. 3. for 400w at 50 c, use 100 lfm fan cooling. conducted emissions en55011/22 class b radiated emissions en55011/22 class a voltage fluctuations en61000-3-3, complies static discharge immunity en61000-4-2, 6kv contact discharge, 8kv air dischar ge radiated rf immunity en61000-4-3, 3v/m. eft/burst immunity en61000-4-4, 2kv/5khz.. line surge immunity en61000-4-5, 1kv differential, 2kv common-mode conducted rf immunit y en61000-4-6, 3vrms power frequency magnetic field immunity en61000-4-8, 3a/m voltage dip immunity en61000-4-11 criteria a @ 250 watts or less. line frequency harmonics en61000-3-2, class a operating temperature 0 to 70 c (see chart) ps on low to inhibit storage temperature -40 to 85 c ps off ttl hi to inhibit operating altitude -500 to 10,000 ft. pwr ok hi when ac is ok, 100-200 msec delay n on - operating altitude -500 to 40,000 ft. pwr ok pf low ? 4 msec warning relative humidity 5% to 95%, non-condensing dc ok hi when output is >95% of nominal vibration 5 hz ? 500 hz, 2.5g rms 5v standby output always on, up to 100ma shock per mil-std-810e, 516.4 part iv fan output 12vdc @ 250ma (turns off during inhibit) GNT400 front end series 400w ac/dc universal input medical & ite power supply 2 year warranty model volts (v) output current ripple total ovp number convection fan cooled & noi se regulation threshold GNT400 output power vs. line voltage & temperature emi/emc compliance environmental specificatio ns auxiliary outputs and signals
___________________________________________________ ___________________________________________________ ________________________ 3 of 4 sl power electronics corp ? 6050 king drive ventura, ca 93003 ? phone 805.486.4565 ? fax 858.712.2040 ? email: info@slpower.com ? www.slpower.com GNT400 front end series 400w ac/dc universal input medical & ite power supply 2 year warranty mounting options
___________________________________________________ ___________________________________________________ ________________________ 4 of 4 sl power electronics corp ? 6050 king drive ventura, ca 93003 ? phone 805.486.4565 ? fax 858.712.2040 ? email: info@slpower.com ? www.slpower.com data sheet ? 2010 sl power electronics corp. the i nformation and specifications contained herein are believed to be correct at the time of publication. rev. 8-27-2010 sl power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. specifications are subject to change without notic e. GNT400 front end series 400w ac/dc universal input medical & ite power supply 2 year warranty mounting options (continued)
|